"items": [
{
"id": 1,
"inspection_area": "201-冶炼主厂房",
"inspection_date": "2026-09-02",
"inspector": "电气自查",
"description": "1 号配电柜进线电缆绝缘层破损,铜芯外露,存在漏电与短路风险",
"suggestion": "停电更换破损段电缆,整改后做绝缘电阻测试并留存记录",
"hazard_unit_id": 1,
"hazard_unit_name": "电气车间",
"person": "李建军",
"due_date": "2026-09-09",
"recheck_person": "李建军",
"rectify_person": "孙浩宇",
"status": "已整改",
"hazard_type_id": 3,
"major": "电气设备",
"minor": "绝缘破损",
"level": "重大隐患",
"remark": "已复查验收,绝缘电阻合格",
"before_images": [
{
"id": "23ee8930-737f-739e-83d0-69076b428b66",
"original_name": "配电柜进线电缆绝缘破损.jpg",
"mime_type": "image/jpeg",
"size_bytes": 512400,
"width": 1600,
"height": 1200
}
],
"after_images": [
{
"id": "83f45373-5982-7707-8003-2f16a4783a0b",
"original_name": "更换后电缆绝缘测试.jpg",
"mime_type": "image/jpeg",
"size_bytes": 498200,
"width": 1600,
"height": 1200
}
],
"created_at": "2026-09-02T10:30:00+08:00",
"updated_at": "2026-09-09T16:05:00+08:00",
"version": 1
},
{
"id": 2,
"inspection_area": "202-熔炼车间",
"inspection_date": "2026-09-05",
"inspector": "电气自查",
"description": "行车滑触线接头处积灰严重,集电器接触不良并偶发打火",
"suggestion": "停电清扫滑触线并紧固接头螺栓,加装防尘护罩",
"hazard_unit_id": 1,
"hazard_unit_name": "电气车间",
"person": "李建军",
"due_date": "2026-09-12",
"recheck_person": "李建军",
"rectify_person": null,
"status": "待整改",
"hazard_type_id": 2,
"major": "电气设备",
"minor": "接线不规范",
"level": "一般隐患",
"remark": null,
"before_images": [
{
"id": "d426a7d4-07b5-7cac-8bcd-f373d8189600",
"original_name": "行车滑触线接头积灰.jpg",
"mime_type": "image/jpeg",
"size_bytes": 512400,
"width": 1600,
"height": 1200
}
],
"after_images": [],
"created_at": "2026-09-05T10:30:00+08:00",
"updated_at": "2026-09-12T16:05:00+08:00",
"version": 1
},
{
"id": 3,
"inspection_area": "301-选矿厂",
"inspection_date": "2026-09-08",
"inspector": "王海涛",
"description": "球磨机检修平台联轴器防护罩缺失,人员靠近时有卷入风险",
"suggestion": "按原图纸补装防护罩并固定牢靠",
"hazard_unit_id": 3,
"hazard_unit_name": "自动化班组",
"person": "陈志远",
"due_date": "2026-09-15",
"recheck_person": "陈志远",
"rectify_person": "周立新",
"status": "整改受阻",
"hazard_type_id": 5,
"major": "安全防护",
"minor": "防护罩缺失",
"level": "重大隐患",
"remark": "防护罩备件到货延迟,已协调采购催货",
"before_images": [
{
"id": "0b71e5c4-484e-748e-8c5a-464e0b28be45",
"original_name": "球磨机联轴器防护罩缺失.jpg",
"mime_type": "image/jpeg",
"size_bytes": 512400,
"width": 1600,
"height": 1200
}
],
"after_images": [],
"created_at": "2026-09-08T10:30:00+08:00",
"updated_at": "2026-09-15T16:05:00+08:00",
"version": 1
},
{
"id": 4,
"inspection_area": "305-硫酸厂",
"inspection_date": "2026-09-06",
"inspector": "电气自查",
"description": "酸泵区照明线路护套开裂,接线盒进线口未做密封",
"suggestion": "更换老化线路并更换防腐蚀接线盒",
"hazard_unit_id": 2,
"hazard_unit_name": "动力车间",
"person": "王海涛",
"due_date": "2026-09-10",
"recheck_person": "王海涛",
"rectify_person": "杨明辉",
"status": "待整改",
"hazard_type_id": 1,
"major": "电气设备",
"minor": "线路老化",
"level": "一般隐患",
"remark": "已超期,现场已加设临时警示围栏",
"before_images": [
{
"id": "f6007e76-2f7c-7df3-899a-7352673240d1",
"original_name": "酸泵区照明线路护套开裂.jpg",
"mime_type": "image/jpeg",
"size_bytes": 512400,
"width": 1600,
"height": 1200
}
],
"after_images": [],
"created_at": "2026-09-06T10:30:00+08:00",
"updated_at": "2026-09-10T16:05:00+08:00",
"version": 1
},
{
"id": 5,
"inspection_area": "401-公辅设施",
"inspection_date": "2026-09-10",
"inspector": "陈志远",
"description": "配电室门口「高压危险」警示标识被油污覆盖,字迹无法辨识",
"suggestion": "清理油污并重新张贴反光警示标识",
"hazard_unit_id": 3,
"hazard_unit_name": "自动化班组",
"person": "陈志远",
"due_date": "2026-09-17",
"recheck_person": "陈志远",
"rectify_person": null,
"status": "待整改",
"hazard_type_id": 4,
"major": "安全防护",
"minor": "警示标识缺失",
"level": "一般隐患",
"remark": null,
"before_images": [
{
"id": "73af22a5-b53b-7a38-8ef7-1ad6a11e0cf7",
"original_name": "配电室警示标识油污.jpg",
"mime_type": "image/jpeg",
"size_bytes": 512400,
"width": 1600,
"height": 1200
}
],
"after_images": [],
"created_at": "2026-09-10T10:30:00+08:00",
"updated_at": "2026-09-17T16:05:00+08:00",
"version": 1
},
{
"id": 6,
"inspection_area": "401-公辅设施",
"inspection_date": "2026-09-11",
"inspector": "电气自查",
"description": "配电室手提式灭火器压力表指针进入红区,已超过检验有效期",
"suggestion": "送检充装或更换同规格灭火器,并更新检验标签",
"hazard_unit_id": 2,
"hazard_unit_name": "动力车间",
"person": "王海涛",
"due_date": "2026-09-18",
"recheck_person": "王海涛",
"rectify_person": "何丽娟",
"status": "待整改",
"hazard_type_id": 6,
"major": "消防设施",
"minor": "灭火器过期",
"level": "一般隐患",
"remark": null,
"before_images": [],
"after_images": [],
"created_at": "2026-09-11T10:30:00+08:00",
"updated_at": "2026-09-18T16:05:00+08:00",
"version": 1
}
],
"page": 1,
"page_size": 20,
"total": 6
}